Industrial sites eat standard cables for breakfast. We learned this brutally during a 2023 Philippine mining project where vibration and rock falls destroyed $200k of conventional fiber in 8 months. Aluminium armoured cable became our salvation – its corrugated metal tape armour absorbs impacts like a shield. According to CRU Group's 2024 study, sites using aluminium armoured cable report 79% fewer cable-related outages.
Here’s the kicker: Many engineers think steel armour is tougher. Let’s settle this:
Property | Steel Armour | Aluminium Armour |
---|---|---|
Crush Resistance | 7000N | 5000N |
Weight (kg/km) | 350 | 210 |
Corrosion Resistance | Prone to rust | Self-protecting oxide |
Cost (per meter) | $1.50 | $1.20 |
EMI Shielding | Magnetic interference | Non-magnetic |
Source: IEEE 2023 Underground Cable Report
Grounding negligence. In 2022, a German factory lightning strike fried 62 armor-grounded cables. Why? They used undersized 10 AWG wires instead of mandated 6 AWG. Aluminium armoured cable requires earthing at BOTH ends per EIA/TIA-607 standard. Otherwise, you’re building a lightning rod.
Problem: Acid fumes dissolving cable jackets
Fix: PTFE-jacketed aluminium armoured cable
Case: BASF’s Louisiana plant reduced replacements from 3x/year to zero since 2021
Problem: -50°C brittleness cracking fibers
Fix: Gel-filled loose tube aluminium tape armour
Pro Tip: Pre-heat reels to 5°C before deployment (we saved $80k in Yukon)
Problem: Rats chewing through conduits
Fix: Double-layer armour with glass yarn buffer
Data: Swiss rail tunnels saw chew damage drop 92% (Alcatel 2024 study)
Www.adsscable.cn
Tension Control: Never exceed 0.5% of cable weight during pulling
Bend Radius: Maintain 20x cable diameter minimum
Grounding: 6 AWG copper wire to earth rods < 5Ω resistance
Termination: Strip armour 15mm back, apply anti-corrosion paste
Testing: OTDR scan at 1550nm 1625nm wavelengths
Hot Trick: Use pulling eyes with swivels – prevents torsion damage
Problem: Saltwater intrusion in offshore rigs
Fix: Double-sealed aluminium armoured cable with hydrogen scavengers
Case: BP’s North Sea platform achieved 0% moisture ingress over 3 years
Www.adsscable.cn
Problem: Motor vibrations fatiguing fibers
Fix: Armour with vibration-dampening EVA underlayer
Data: Extends MTBF by 300% (Siemens Energy Test Report 2023)Www.adsscable.cn
“But aluminium conducts electricity!” True, but here’s the twist: Aluminium armoured cable uses corrugated tape not solid wire. This creates discontinuous conductivity, preventing ground loops. Just remember: Always ground at termination points!
- [ ] IEC 60794-1-2E3 crush certification - [ ] Corrosion index > Class 4 (ISO 9223) - [ ] Water-blocking powder in core - [ ] Central FRP strength member - [ ] LSZH jacket for indoor segments - [ ] OTDR loss < 0.4 dB/km at 1550nm
Q: Can aluminium armour be used in explosive zones?
*A: Absolutely – it meets ATEX/IECEx Zone 1 when paired with Ex e glands.*
Q: How to repair damaged armour?
*A: Use 3M FJB-100 kit – restores 90% crush resistance.*
Q: Minimum bending radius during install?
A: 20x cable diameter (e.g., 120mm for 6mm cable).
Q: Difference between tape vs wire armour?
A: Tape offers better crush resistance; wire provides higher tension strength.
Q: Why choose aluminium over stainless steel armour?
A: 40% lighter, 30% cheaper, and won’t interfere with MRI equipment.